A heavy workday with the BLE Gateway in the test laboratory

The BLE Gateway has been developed with its robust rubber amour for the use in harsh environments. For example, it is used in the H2S application in the sewer tunnel.

You think that a sewer tunnel is not a nice working environment? You are probably right. However, for our BLE Gateway, things are getting worse that day.

In the test laboratory of TÜV Süd, it was put through its paces and had to endure a lot. It was exposed to dust and water, even high-pressure cleaner. As a small spoiler, we would like to tell you that it passed all tests.

It gets dusty

To ensure that no solid foreign objects penetrate into the housing, the BLE Gateway was dusted for 8 hours. A vacuum of 20mbar and 2kg/m³ talcum were used. However, the BLE Gateway left this completely unmoved and no dust particle managed to penetrate the housing. The IP6x test was successfully passed.

BLE Gateway Prüfung IP6x

Off into the cool water

Even if a jump into cold water promises an excellent cooling for people on such hot days, electronic devices do not like water at all. The BLE Gateway was exposed to strong jet water (water flow rate 100 l/min) for 3 minutes from a distance of 2.5 to 3 metres. During this test the robust rubber housing did a great job. The water could not infiltrate into the housing and the IPx6 test was successfully completed.

BLE Gateway Prüfung IP66

Hold one’s breath

For the IPx8 test the BLE gateway had to hold its breath. For 5 hours it had to stay one meter under water. Look and be amazed, the BLE Gateway passed this test with flying colours.

BLE Gateway Prüfung IP68

Let the water flow

In the final IPx9 test drastic measures were taken. It had to be possible to somehow get at least one drop of water into the BLE Gateway.

The BLE Gateway was placed on a rotating worktable. 4 high-pressure cleaners pointed threateningly at different angles (0°, 30°, 60°, 90°) to the BLE Gateway. And then the water flows. Water with a temperature of 80° Celsius with a jet pressured of 80 to 100 bar and a distance of 12.5 cm was released onto the BLE Gateway form each position for 30 seconds.

After this difficult test, the BLE Gateway suffered some optical losses and the otherwise so smooth surface was roughened. Nevertheless, no water droplets were able to infiltrate the BLE Gateway.

BLE Gateway Prüfung IP69

IP66 / IP68 / IP69

After such a heavy workday our BLE Gateway wishes to return to its natural environment. Receiving data from BLE sensors, for example from H2S sensors or from a pressure sensor, as in the myDatalogGauge application, processing them and transmitting them securely to the central server is kind of easy compared to the tasks and tests that the BLE Gateway had to perform in the test laboratory.

https://youtu.be/yFHgOIuJQxY

The meaning of the different IP protection classes

In one of our “Did you know?” articles we have summarized the explanation of the different IP protection classes for you.

If you operate your application in a potentially explosive atmosphere, strict guidelines apply and the device must meet further requirements. Read more in “Did you know: ATEX Zone1 – Why?”